F125 |
F200 |
F450 |
| Fuel Consumption |
| Gallons per Hour (GPH) |
.84 |
1.68 |
3.6 |
| BTUH |
| Input/Output (x100) |
125/100 |
240/200 |
450/382 |
| Dimensions |
| Height (with burner on F450) |
24" |
36" |
40" / 54" |
| Width (with burner on F200) |
24" |
38" |
40" |
| Length (with blower & burner on F125) |
84" |
37" |
55" / 79" |
| Stack |
| Inches of Diameter |
6" |
8" |
8" |
| Height (without elbows) |
10' |
12' |
14' |
| Draft (inches of water) |
-0.03 to -.04 |
-0.03 to -.04 |
-0.03 to -.04 |
| Compressed Air Requirements |
| SCFM (maximum) |
2 |
2 |
2 |
| PSIG |
30 |
30 |
30 |
| Air Connection |
| Fitting Size to Air Regulator |
1/4 NPT |
1/4 NPT |
1/4 NPT |
| Flame |
| Length - Changes with Oil Pressure (Avg) |
2' |
3-1/2' |
4' |
| Diameter - Approximate |
10" |
12" |
18" |
| Air Tube |
| Diameter - Enters into combustion chamber |
4" |
4" |
5" |
| Length - Inside of combustion chamber |
1-5/8" |
1-5/8" |
4-1/2" |
| Opening - Into combustion chamber of furnace |
4-1/4" |
4-1/4" |
5-1/4" |
| Convenience Controls |
| Additional attempts to establish flame |
Yes |
| Automatic nozzle clean-out |
Yes |
| Hour Meter |
Yes |
| Dirty filter indicator |
Yes |
| Switch to test spark ignition |
Yes |
| Cabinet Construction |
| Material Gauge, Aluminum |
12 |
14 |
14 |
| Weight (pounds) |
350 |
450 |
850 |
| Furnace Air Movement
via Prop or Squirrel Cage Blower |
| Blower Motor (HP)* |
1/3 |
1/2 |
1-1/2 |
| Capacity - CFM (max) |
1,000 |
2,400 |
4,000 |
| Motor Speed (RPM) |
1,100 |
1,100 |
1,725 |
| Outlet Openings |
6" |
25" |
36" x 35" |
| Static Pressure - blower unit only (in. - H20) |
n/a |
n/a |
.25 - .4 |
| Electrical |
| Total current draw (in amps) - maximum |
17 |
| Volts |
120 |
120 |
240 |
| Required circuit protection (in amps) |
20 |
| Frequency - Hz |
60 |
| Thermostat Voltage |
120 |
| Ignition Transformer, 23 ma secondary, continuous duty shielded
transformer |
10,000V |
| Intermittent spark ignition (10 seconds) |
Yes |
| Burner Motor |
| Horsepower |
1/5 |
| RPM |
3,450 |
| Fuel Pump |
| Suntec Model A2RA Waste Oil Pump |
Yes |
| Oil Nozzle |
| Delavan Aspirated Nozzle |
#30609-3.1 |
#30609-3.1 |
#30609-5 |
| Equipment Provided |
| Vapor elimination from oil |
Yes |
| Filtration after oil heating |
Yes |
| Heater Switch |
Included |
| Line voltage thermostat |
Included |
| Barometric Damper |
Included |
| Floating oil pickup assembly |
Included |
| Check Valve |
Included |
| Return flow vent system |
Included |
| Installation & Maintenance Manual |
Included |
| Warranty - One
yr full warranty on parts (not labor), 10 yr limited on furnace
cabinet |