Multi-Fuel
Boilers
INOV8 was the first in the waste oil burning industry to offer
a boiler capable of burning waste oil as its fuel. Now a decade
later we have a full line of high quality fully cleanable
cast iron boilers ranging from 200,000 to 1,000,000 BTUs per
hour. The German made sectional boiler has a front door that
the burner mounts onto. When opened you have full access to
the nozzle, the combustion chamber and all flue passageways
for easy removal of ash. The boilers offer unlimited heating
options for businesses that generate waste oil. |
| The same INOV8 burner used with furnaces and
evaporators provides unequaled safety, reliability and the
cleanest emissions in the industry. When the boiler is operating
there will be no smoke and no blackened chimney. The average
boiler efficiency is 85%. In-floor radiant heat typically
saves 25 to 40% over conventional heating methods. That efficiency
combined with burning waste oil; you can virtually eliminate
all heating bills. Businesses are further benefiting in ways
that would otherwise be too cost prohibitive with conventional
fuels. INOV8 boilers are being used in a variety of businesses:
in marinas, green houses, quick lubes, car washes, truck
stops, factories, wood kilns, an electric utility company,
and in lots of car/truck dealerships and service companies.
INOV8 engineers provide free assistance in plan design and
equipment selection. |

Cleaning accessibility is made easy with the swing door on
the combustion chamber. In fact, the boiler can be thoroughly
and properly cleaned in a fraction of the time is takes to
clean a conventional boiler, since it does not require disassembly. |
Boilers can be sized to meet any heat load requirement.
Multiple installations are great for staging boilers to meet
varying loads. INOV8 has developed a relay specifically for
staging multiple boilers so that the last boiler on is also
the last boiler that shuts off. This distributes the load
evenly between the boilers. |
Boiler Technology
INOV8 International, Inc. manufacturers the premiere line
of waste oil burning equipment. Our patented systems provide
an EPA approved method of disposing of used oils, while solving
the disposal and liability concerns. Waste oil boiler systems
are rapidly growing in popularity due to the great flexibility
and benefits they provide when used in a variety of applications
where hot water is needed.
Burning used oils has been popular for nearly two decades
but it hasn't been until recently that technology has advanced
to allow the safe and clean burning of these oils. The detergency
package inherent to waste oil along with the accumulated
wear metals from the engines constitutes many non-burnables
that end up as an ash through the combustion process. It
is necessary and critical to have a cleanable boiler to
accommodate the frequent cleaning. INOV8 has selected a
high quality, high efficiency boiler that is cleanable.
Simply remove two bolts and swing out the burner door to
expose all of the passageways for cleaning with a brush
and vacuum cleaner and allow the boiler to be placed back
in service within fifteen minutes. Through our continued
development work we have learned of many situations associated
with the burning of waste oil in a boiler. INOV8 has included
solutions in our standard boiler product line for all situations.
In fact, we are so convinced of the necessity of these various
solutions that we will not sell a boiler unless all recommended
modifications are included in the installation. Even with
these cost-adding modifications, the INOV8 boiler remains
cost effective and very competitive.
Many waste oil burner manufacturers have attempted to arbitrarily
use their burners with boilers without success or an understanding
why they failed. Evidence of this can be seen in the constant
changing of boilers selected by waste oil burner manufacturers.
None of the systems can match the quality, workmanship,
warranty, flexibility, efficiency and safety provided by
the combination INOV8/Buderus waste oil boiler systems.
INOV8 selected Buderus boilers after extensive testing starting
in 1992 and continues to use them today. We sponsored several
field studies in which boiler systems were installed at
customer sites that were monitored closely by INOV8. Through
those experiences we learned of the importance of proper
installation, proper boiler temperatures, proper cleaning
procedures, necessary controls, required safety devices,
and a series of modifications to both the boiler and burner
to allow efficient and safe operation while burning used
crankcase oils. |
| Features |
- Factory assembled cast iron section (can be ordered
knocked-down)
- Supply and return connections at rear of boiler
- Flexible GL-180M cast iron with silicon “barrier
skin”
- Precision casting eliminates need for manual grinding
- Tongue and groove flueside sealing for pressurized operation
- Boiler installation manual
- Modifications to boiler door & liner
- Floating pickup assembly, includes: filter housing,
check valve, float on oil line
|
- Jacket packaged separately in box
- Full-size burner door hinged left or right (field adjustable)
- Blue enamel jacket with 3 ½” wrap-around
thermal insulation
- No refractory or target cup needed due to chamber geometry
- Precision machined steel push nipple sectional construction
- Boiler brush
- Appropriately sized burner
- Appropriately sized draft inducer
- INOV8 boiler instruction manual
- Spare fuses
|
| INOV8 International boiler packages are the combination of a Buderus boiler
that has some modifications to accept an
INOV8 burner and to handle the unusual characteristics of
waste oil as its fuel. The output of the boilers may vary
based
on the type of waste oil. The boilers shall be of full three-pass
design, suitable for forced draft firing and capable of
achieving combustion efficiencies of 85% at full firing rate.
The boiler shall bear the ASME stamp and IBR rating. The
INOV8 burner shall bear the Underwriters Laboratory listing
in the United States and in Canada. |
| |
|
|
Boiler Dimensions |
|
|
|
Burner Dimensions |
| Model# |
Input BTU |
GPH |
Height |
Width |
Length |
Boiler Dry
Weight |
Water Connection |
Burner
Model # |
Height |
Width |
Length |
| B225 |
225,000 |
1.60 |
34" |
23" |
51" |
600 |
1-1/2" |
BO-200 |
14" |
18" |
16" |
| B275 |
275,000 |
1.96 |
34" |
23" |
56" |
700 |
1-1/2" |
BO-201 |
14" |
18" |
17" |
| B325 |
325,000 |
2.32 |
34" |
23" |
61" |
800 |
1-1/2" |
BO-202 |
14" |
18" |
18" |
| B400 |
400,000 |
2.85 |
41" |
35" |
60" |
1,197 |
2" |
BO-203 |
14" |
18" |
19" |
| B500 |
500,000 |
3.50 |
41" |
35" |
66" |
1,391 |
2" |
BO-204 |
14" |
18" |
20" |
| B650 |
650,000 |
4.60 |
41" |
35" |
73" |
1,585 |
2" |
BO-205 |
14" |
18" |
21" |
| B750 |
750,000 |
5.35 |
41" |
35" |
79" |
1,779 |
3" |
BO-700 |
19" |
24" |
25" |
| B850 |
850,000 |
6.07 |
41" |
35" |
85" |
1,973 |
3" |
BO-701 |
19" |
24" |
25" |
| B1050 |
1,050,000 |
7.50 |
52" |
38" |
89" |
3,059 |
4" NPT |
BO-702 |
19" |
24" |
25" |
Back to Top
|
|